PROGRAMMING

Precaution
Before programming the system data for MCI, confirm that the system is under the following status.
• The system is under On-Line mode ("RUN" lamp is flashing on the MP card).
• The AP00 card is mounted in the correct location (for MCI with AP00).
• All the system data pertaining to the station, trunks, and service features are already programmed.
Station Number Data Loading
The AP00 stores the station number data loaded from the MP. When station numbers have been added,
deleted or changed by CM10, the station number data must be reloaded to the AP00 by the following pro-
cedure.
(1)
Flip the MB switch of the AP00 to UP position.
(2)
Return the MB switch to DOWN position.
(3)
The "**** AP00 START ****" message is printed if a printer is provided.
(4)
The "SORT COMPLETE" message is printed when the station number has been sent to the AP00.
MESSAGE CENTER INTERFACE (MCI)
– 461 –