CM08
Specify the replay timer of the message
recorded in the Digital Announcement Trunk.
CM20
To record, replay, and delete a message, assign
the Digital Announcement Trunk access
codes, respectively.
CM41
Specify the unanswered timing of message
replay.
Specify the Attendant Delay Announcement
connection timer.
Specify the interval time of message replay.
END
HARDWARE REQUIRED
DAT card or MP card (built-in DAT)
DESCRIPTION
ATTENDANT DELAY ANNOUNCEMENT
(1)
165
(2)
0 : Replay at an interval assigned by
CM41 Y=0>47
1 : Replay only once
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code
(2)
A100: Record
A101: Replay
A102: Delete
Y=0
(1)
16
(2)
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.
Y=0
(1)
67
(2)
01-32: 4-128 seconds
(4 second increments)
If no data is set, the default setting is 8-12 sec-
onds.
Y=0
(1)
47
(2)
01-30: 4-120 seconds
(4 second increments)
If no data is set, the default setting is 32-36 sec-
onds.
– 80 –