To provide PMS with AP00 on RS-232C:
START
CMD001
Assign the attribute data, depending on the
port (Port 0-3) connected to PMS.
PORT 0 PORT 1 PORT 2 PORT 3
20
21
22
23
80
81
82
83
84
85
86
87
89
90
91
92
93
94
95
96
98
A
DESCRIPTION
AP00 INITIAL
1ST DATA
24
28
32
Data speed
25
29
33
Stop bit length
26
30
34
Data length
27
31
35
Parity
100
120
140
Function
101
121
141
Priority for data processing
102
122
142
Message Format
103
123
143
Number of lines per page
104
124
144
Protocol
105
125
145
Station Address (SA)
106
126
146
Unit Address (UA)
107
127
147
Timer for detecting the terminal/no answer
109
129
149
Timer for detecting the end of block
110
130
150
Timer for detecting non data communication
111
131
151
Number of times to resend the Selecting
Sequence when NAK is returned in Phase 2
112
132
152
Number of times to resend the Selecting
Sequence when no answer in Phase 2
113
133
153
Number of times to resend the Selecting
Sequence when NAK is returned in Phase 3
114
134
154
Number of times to resend the Selecting
Sequence when no answer in Phase 3
115
135
155
Delay before resending the Selecting
Sequence when NAK is returned
116
136
156
Delay before resending the text when WABT is
returned
118
138
158
Guard timer between texts
HOTEL SYSTEM PROGRAMMING
PROPERTY MANAGEMENT SYSTEM INTERFACE
(1)
See the following table.
(2)
See the following table.
MEANING
– 822 –
DATA
: Initial Data
2ND
MEANING
DATA
2/3/4/5
1200/2400/4800/
NOTE 1
9600 bps
0
/1/2
1/1.5/2 bits
0
/1
7/8 bits
0
/1/2
None Parity/
Even Parity/Odd
Parity
4
PMS
NOTE 2
0
1st Priority
6
PMS Format
0
Not used
6
IMS Procedure
49
1
33
!
8
1 second
70
35 seconds
70
35 seconds
3
3 times
15
15 times
3
3 times
32
15 times
24
3 seconds
24
3 seconds
0
Not used
NWA-008845-001 Rev.5.0