Philips Sopho 2000 IPS User Manual page 708

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

B
CM35
Assign the appropriate data for the characteris-
tic of the distant PBX.
C
DESCRIPTION
Y=09 Incoming Connection Signaling
(1)
00-63: Trunk Route No. (01/02)
(2)
03: Wink Start
04: Delay Dial
05: Immediate Start
06: 2nd Dial Tone/Timing Start
Y=10 2nd DT sending on call termination
(1)
00-63: Trunk Route No. (01/02)
(2)
0 : No Tone
1 : 2nd Dial Tone
Y=13 Maximum Number of Sending Digits
(1)
00-63: Trunk Route No.
(2)
001-254: 1-254 digits
If no data is set, sender is released when time out
occurs or the called station answers.
Y=20 Sender start condition
(1)
00-63: Trunk Route No. (01/02)
(2)
00 :Wink Start
01 :Delay Dial
15 :Timing Start (Prepause per CM35
Y=21)
The above data should be set to each route ac-
cording to the data for CM35 Y=09, as shown
below.
Data for
CM35 Y=09
03
04
05
06
Y=21 Sender Prepause Timing
(1)
00-63: Trunk Route No.
(2)
00: 0 second
01: 0.5 seconds
02: 1.0 second
03: 1.5 seconds
04: 2.0 seconds
05: 2.5 seconds
06: 4.0 seconds
07: 5.0 seconds
– 690 –
TIE LINES
DATA
Data for
CM35 Y=20
00
01
15
15
08 : 6.0 seconds
09 : 7.0 seconds
10 : 8.0 seconds
11 : 9.0 seconds
12 : 10.0 seconds
13 : 11.0 seconds
14 : 12.0 seconds
15 : 3.0 seconds
NWA-008845-001 Rev.5.0
32ch1011.fm
DECEMBER/02/2005

Hide quick links: