A
CM30
CM45
Assign the PB (DTMF) Receiver for only
Automated Attendant, if desired.
CM63
Specify whether inter-tenant connection is
allowed on an Automated Attendant incoming
call.
CM64
Assign the answering method for the Automat-
ed Attendant, to the required tenants.
For providing a Night Message, assign the
answering method of Night Mode, to the
required tenants.
B
DESCRIPTION
•
Y=33 Handling of all PBR busy when
Y=30, 31 is set to data 08
(1)
000-255: Trunk No.
(2)
00 : C.O. line release
01 : Forwarded to TAS indicator
03 : Forwarded to Attendant Console
15 : C.O. line release
•
Y=2
(1)
XX Z: PB Receiver No.
XX : 00 (Built-in PBR on MP card)
01-15 (8RST Card No. assigned by
CM10/CM14, E201-E215)
Z
: 0-3 (Circuit No.)
(2)
0: Only for Automated Attendant
•
Y=2
(1)
XX ZZ
XX: 00-63 (Tenant No. of called station)
ZZ : 00-63 (Tenant No. of trunk)
(2)
0 : Restricted
1 : Allowed
•
Y=0
(1)
00-63: Tenant No.
(2)
00 : DT Connection
01 : Hold Tone on MP card + DT
Connection
02 : 1st Answering Message + DT
Connection
03 : DT Connection
•
Y=2
(1)
00-63: Tenant No.
(2)
00 : DT Connection
01 : Hold Tone on MP card + DT
Connection
02 : Night Message assigned by CM49
Y=00, 02XX
03 : According to the data set by CM64
Y=0
– 90 –
AUTOMATED ATTENDANT
DATA
NWA-008845-001 Rev.5.0