A
CM40
Specify the function for the RS ports.
NOTE:
When a port is used for Built-in
SMDR, assign the 2nd data=14.
When a port is used for both MCI
and Built-in SMDR, assign the 2nd
data=11.
Assign the attribute data for RS ports accord-
ing to the SMDR terminal specifications.
B
DESCRIPTION
STATION MESSAGE DETAIL RECORDING (SMDR)
Y=00 Function
(1)
0: Port 0
1: Port 1
(2)
11: MCI and Built-in SMDR
14: Built-in SMDR
Y=01 Data length
(1)
0: Port 0
1: Port 1
(2)
0 : 7 bits
1 : 8 bits
Y=02 Parity check
(1)
0: Port 0
1: Port 1
(2)
0 : Effective
1 : Ineffective
Y=03 Kind of parity
(1)
0: Port 0
1: Port 1
(2)
0 : Even parity
1 : Odd parity
Y=04 Stop bit
(1)
0: Port 0
1: Port 1
(2)
0 : One-stop bit
1 : Two-stop bits
Y=05 DTR signal
(1)
0: Port 0
1: Port 1
(2)
0 : Low
1 : High
– 626 –