Philips Sopho 2000 IPS User Manual page 363

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

D
CM41
NOTE 1:
• When immediate ringing is sent from the main PBX (Centrex), CM41 Y=2>40 plus
CM41 Y=2>41 must be assigned as longer time than the time assigned by CM41
Y=2>00.
• When immediate ringing is not sent from the main PBX (Centrex), CM41 Y=2>40 must
be assigned as longer time than the time assigned by CM41 Y=2>00.
• Check the main PBX (Centrex) ringer cycle and set as shown below:
Main PBX Ringing
(Station termination)
Main PBX Ringing
(C.O. termination)
When the gap between the main PBX station terminating ringer and C.O. line
terminating ringer is under 200 ms., distinction may be incomplete.
NOTE 2:
When Immediate Ringing is not provided on main PBX, be sure to set CM41 Y=2>41 as 00.
CM90
Assign the Trunk Line Appearance key to a
term
D
.
Provide the tone ringer on call termination.
NOTE:
When CM30 Y=02/03/40/41 2nd
data is 03, this setting is required.
END
DESCRIPTION
B seconds<"CM41 Y=2>40 setting time">A seconds
A seconds
B seconds
Y=00
(1)
My Line No. +
(2)
D000-D255: Trunk No.
Y=01
(1)
My Line No. +
(2)
0 : Disabled
1 : Enabled
– 345 –
DISTINCTIVE RINGING
DATA
,
+ Key No.
,
+ Key No.
NWA-008845-001 Rev.5.0