No Cid Call Routing - Philips Sopho 2000 IPS User Manual

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

NO CID CALL ROUTING

[Series 3600 software required]
• For Direct Inward Dialing calls
START
CM35
Assign the indication of reason why the calling
number is not informed from network to trunk
route.
CM76
Assign whether the call terminating method is
specified for DID incoming call with no CLI.
NOTE:
Assign the specification of the call terminating
method for DID incoming call with no CLI.
A
DESCRIPTION
Assign the call terminating method
by CM76 Y=34/36 when this com-
mand is set to 0/1.
Y=133
(1)
00-63: Trunk Route No.
(2)
0: To indicate
Y=33 (For Day Mode)
Y=35 (For Night Mode/Mode A/Mode B)
(1)
000-999: Block No.
(2)
0 : Specified when reason of the incom-
ing call with no CLI is "privacy"
1 : Specified for all incoming calls with
no CLI
3 : Not specified
Y=34 (For Day Mode)
Y=36 (For Night Mode/Mode A/Mode B)
(1)
000-999: Block No.
(2)
0 : To transfer to the DAT/another station/
Attendant console (assigned by CM51
Y=33)
1 : To reject the call termination
2 : To terminate the D
LED indication/unusual ringer tone/
unusual ringer pattern (assigned by
CM76 Y=37, 38, 39)
3 : To terminate as usual
– 548 –
NO CID CALL ROUTING
DATA
term
with unusual
NWA-008845-001 Rev.5.0
32ch1009.fm
JULY/01/2006