Philips Sopho 2000 IPS User Manual page 743

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

To provide an external indicator for UCD Call Waiting:
START
CM08
Assign the incoming call to queuing mode
when all UCD stations are busy.
CM42
Specify the maximum number of queuing in
each UCD group for controlling external indi-
cator.
NOTE:
N=Number of queuing station/trunk
CONDITIONS
2nd Data=01
N
<
2nd Data (2nd Data≠01)
2nd Data
CM10
Assign the DK card to the required LEN.
NOTE 1:
CM14
Assign the DK card to the required LEN.
[Series 3200 R6.2 software required]
NOTE 1:
A
DESCRIPTION
Depending on the number of queuing station/trunk, lamp indication pattern on the external
indicator is different as shown below:
N (2nd Data≠01)
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
The DK card number must be as-
signed to the first LEN (Level 0) and
the third LEN (Level 2) of each LT
slot.
UNIFORM CALL DISTRIBUTION (UCD)
(1)
212
(2)
1 : Queuing
(1)
15
(2)
01-99
NONE : 1 call
LAMP INDICATION
Lamp on irrespective of number of queuing station/trunk (For the indi-
cation pattern, see CM59 in next page.)
Lamp off
Lamp on (For the indication pattern, see CM59 in next page.)
(1)
000-763: LEN
(2)
E800-E831: DK Card No.
For PIM0/1: E800-E807
For PIM2/3: E808-E815
For PIM4/5: E816-E823
For PIM6/7: E824-E831
NOTE 2:
(1)
XX ZZZ: LEN
XX : 00-59: FP No.
ZZZ: 000-127: Port No.
(2)
E800-E831: DK Card No.
For FP No. 00: E800-E807
For FP No. 01: E808-E815
For FP No. 02: E816-E823
For FP No. 03: E824-E831
NOTE 2:
– 725 –
CALL WAITING INDICATION-UCD
DATA
: 1 call-99 calls
Circuit No. 3 of E831 is used for
built-in External Equipment Interface
on MP card by setting CM44.
Circuit No. 3 of E831 is used for
built-in External Equipment Interface
on MP card by setting CM44.
NWA-008845-001 Rev.5.0
32ch1011.fm

Hide quick links:

Advertisement

Table of Contents
loading