B
CM67
Assign the automatic clock change pattern to
each location number.
Set the daylight-saving time to each location.
NOTE:
Usually do not set this command by
MAT/CAT. This command is set auto-
matically when automatic system clock
change has been executed by CM43
Y=8/CM67 Y=31
If the system power is off at the time
for clock change, set this data.
CM08
Specify the system clock used for the SMDR
output of outgoing/incoming call.
Specify the system clock used for the SMDR
output of station to station call.
Specify the system clock used for the date pat-
tern/time pattern in LCR service.
END
DESCRIPTION
.
AUTOMATIC CHANGE TO DAYLIGHT SAVING TIME
Y=31
(1)
00-63: Location No.
(2)
0
1
NONE : Automatic clock change is not
Y=30
(1)
00-63: Location No.
(2)
0
NONE : To operate with Standard Time
(1)
836
(2)
0 : System clock of the site that the seized
trunk is accommodated (for outgoing
call)/System clock of site that the ter-
minated trunk is accommodated (for
outgoing call)
1 : System clock of Main Site
(1)
837
(2)
0 : System clock of the site that the seized
trunk/calling station is accommodated
1 : System clock of Main Site
(1)
904
(2)
0 : System clock of the site that the seized
trunk/calling station is accommodated
1 : System clock of Main Site
– 116 –
DATA
: Change Pattern 0 (assigned by
CM43 Y=8>00/01)
: Change Pattern 1 (assigned by
CM43 Y=8>04/05)
provided
: To operate with Daylight-Saving
Time
NWA-008845-001 Rev.5.0