A
CM08
Specify ON/OFF condition for external relay/
external key on MP built-in DK00 card.
CM44
Assign the External Announcement Machine
start function to the DK card.
CM90
Assign the Timed Reminder feature access key
term
to the D
s, if required.
CM08
Specify the timing for Timed Reminder start.
CM41
Specify the ringing duration of a Timed Re-
minder call.
Specify the duration of a Timed Reminder call.
B
DESCRIPTION
(1)
700
(2)
0 : ON (Ground Start)
OFF (Ground Off [Open])
1 : ON (Ground Off [Open])
OFF (Ground Start)
(1)
XX Y
XX : 00-31: DK Card No. assigned by
CM10/CM14 (E800-E831)
Y : 0-3: Circuit No.
313: MP built-in External Equipment Inter-
face
(2)
0100: External Announcement Machine
for Timed Reminder Calling
Y=00
(1)
My Line No. +
(2)
F0024
(1)
228: Timed Reminder start timing
(2)
0 : At preset time
1 : Before 5 minutes of preset time
Y=0
(1)
23
(2)
02-14: 8-56 seconds
If no data is set, the default setting is 28-32 sec-
onds.
Y=0
(1)
52
(2)
01-99: 4-396 seconds
If no data is set, the default setting is 60-64 sec-
onds.