STATION HUNTING

STATION HUNTING-CIRCULAR

PROGRAMMING
START
CM18
To set up each Station Hunting group, assign
station numbers, one by one, in order of the
Hunting as shown below.
Example: For setting station number 200,
1st Operation
2nd Operation
3rd Operation
Specify the Hunting capability of each station.
To continue the hunt in the original direction,
if the station is busy, set to "1"; to reverse the
direction (last station only), set to "5".
NOTE 1:
NOTE 2:
NOTE 3:
CM08
Allow or restrict the ability to set Station Hunt-
ing-Circular for a station with Do Not Disturb
set.
END
DESCRIPTION
201, 202 into one Hunting group.
(1) 200
(2) 201
1st
(1) 201
(2) 202
(1) 202
201
(2) 200
The maximum number of stations
per hunt group is 60. And there is no
limit to the number of Circular Hunt
groups within the system.
Each station can belong to only one
hunt group.
The Attendant Console cannot be
member of a hunt group.
Y=0
(1)
X-XXXXXXXX: Station No. to be includ-
(2)
X-XXXXXXXX: Another Station No. to
200
3rd
202
2nd
Y=1
(1)
X-XXXXXXXX: Station No.
(2)
1: If busy, hunt in original direction
5: If busy, hunt in reverse direction
(1)
240
(2)
0 : Allow
1 : Restricted
– 612 –
STATION HUNTING
STATION HUNTING-CIRCULAR
DATA
ed in Station Hunting
Group
be linked
NWA-008845-001 Rev.5.0