B
CM35
CM35 Y=19 DTI PAD
CONNECTION
PATTERNS
Station-DTI
Tone-DTI
COT/DID/ODT
(2W E&M)/IPT-
DTI
ODT (4W E&M)-
DTI
DTI/BRT/PRT/
CCT/Virtual IPT-
DTI
T/R: Transmitter PAD/Receiver PAD
+ : Gain
: Loss
C
DESCRIPTION
PAD DATA OF DTI [dB]
DAT
DAT
DAT
A=4
A=5
A=6
(T/R)
(T/R)
(T/R)
–3/–8 –3/–3 –3/–3 –3/–8
0/0
0/0
0/0
0/0
0/0
0/0
+3/–3
0/0
0/0
0/–6
0/0
0/–6
Y=01 Dialing signal type
(1)
00-63: Trunk Route No.
(2)
7 : DP/DTMF (Incoming)
DTMF (Outgoing)
Y=04 Answer signal from distant office
(1)
00-63: Trunk Route No.
(2)
2: Answer signal arrives
Y=05 Release signal from distant office
(1)
00-63: Trunk Route No.
(2)
1 : Release signal arrives
Y=09 Incoming connection signaling
(1)
00-63: Trunk Route No.
(2)
03: Wink Start
04: Delay Dial
05: Immediate Start
06: 2nd DT/Timing Start-Tie line
Y=19 DTI PAD
(1)
00-63: Trunk Route No.
(2)
0-3 : Programmable PAD (See CM42)
4-7 : Fixed PAD (See left table)
DAT
A=7
Y=20 Sender start condition
(T/R)
(1)
00-63: Trunk Route No.
(2)
00 : Wink Start
01 : Delay Dial
0/0
02 : Ground Start
15 : Timing Start
0/0
+3/–3
0/0
– 284 –