Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Deactivate modal cycles or modal macro calls if one of the above mentioned G functions has been programmed.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12724
[Channel %1: ] Block %2 no radius programmed for cylinder interpolation activation/
deactivation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When programming G07.1 (cylinder interpolation TRACYL), no cylinder radius has been programmed. Selection of
the cylinder interpolation (TRACYL) with G07.1 C <cylinder radius> deselect with G07.1 C0. For "C" the name of the
rotary axis defined in the TRACYL machine data has to be programmed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
G07.1 block, program the cylinder radius under the name of the rotary axis for the cylinder interpolation.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12726
[Channel %1: ] Block %2 illegal plane selection with parallel axes
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In a block with plane selection (G17 _ G19), a basic axis of the coordinate system must not be programmed together
with the parallel axis assigned to it.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
For plane selection with G17, G18, G19 either program the basic axis of the coordinate system or the assigned parallel
axis.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
12728
[Channel %1: ] Block %2 distance for double turret not set
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The tool clearance for the double turret head in the SD42162 $SC_EXTERN_DOUBLE_TURRET_DIST is 0.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Enter tool clearance for the double turret head in the SD42162 $SC_EXTERN_DOUBLE_TURRET_DIST.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: