Conditional stop at end of block /CONDITIONAL_STOPATEND/ No. 73
Definitions:
Conditional stop at the block boundary. There is another stop if there is
still a stop reason "Stop at end of block" after continuation by an NC start.
Should not occur in any alarm
Conditional stop at end of block (SBL2) /CONDITIONAL_SBL_DEC_STOPATEND/ No. 74
Definitions:
Conditional stop at the block boundary. Despite Start, the interpreter
or preprocessing does not bring any blocks into the main run.
Should not occur in any alarm
Continue block search /BLOCKSEARCHRUN_CONTINUE/ No. 50
Definitions:
Continue block search (NC block: = Stopre)
Should not occur in any alarm
Continue block search /BLOCKSEARCHRUN_RESUME/ No. 52
Definitions:
Continue block search (PI command)
Should not occur in any alarm
Continue interpreter processing /CONTINUE_INTERPR/ No. 91
Definitions:
Start the continuation of the interpreter processing (internal preprocessing stop)
Should not occur in any alarm
Continue program execution /RESUMEPROG/ No. 26
Definitions:
Start continue program execution,
(VDI signal, NC start)
Not permitted if:
1. Program status is active,
2. An alarm response is pending:
3. Reference point approach not yet executed.
Possible actions:
1. None
2. Execute alarm clear condition.
3. Execute reference point approach
Continue program in Teach-in /RESUME_TEACHINPROG/ No. 83
Definitions:
Continue a program in the teach-in submode.
(VDI signal, NC start)
See STARTSIG and MODESWITCHTOAPROGMODE
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
which prevents a start,
or compels braking.