Block %2: Incorrect Tool Point Direction Programmed; Block %2: Shape Incorrectly Defined; Block %2: No Infeed Depth Programmed; Block %2: No Point Of Intersection Found - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

61608
[Channel %1: ] Block %2: Incorrect tool point direction programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE94, CYCLE96.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
A cutting edge position 1...4, matching the undercut form, must be programmed.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61609
[Channel %1: ] Block %2: Shape incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE94, CYCLE96, LONGHOLE, POCKET3, SLOT1.
Remedy:
Check parameter for the undercut form or groove form or pocket.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61610
[Channel %1: ] Block %2: No infeed depth programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE76, CYCLE77, CYCLE96.
Remedy:
Check parameter MID.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61611
[Channel %1: ] Block %2: No point of intersection found
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No intersection could be calculated with the contour. Alarm triggered by following cycle: CYCLE95.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check contour programming or modify infeed depth.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61612
[Channel %1: ] Block %2: Thread finishing not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE97, CYCLE98.
Remedy:
Check the conditions for thread finishing.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
465

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d