14761
[Channel %1: ] Block %2 motion synchronous action: DELDTG function not allowed
with active tool radius compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Rapid delete distance-to-go for synchronous actions is not allowed with DELDTG when tool radius compensation is
active.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Deactivate tool radius compensation before performing rapid delete distance-to-go and then reselect
or
as of SW 4.3: "Delete distance-to-go without preparation".
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14762
[Channel %1: ] Block %2 too many PLC variables programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The number of programmed PLC variables has exceeded the maximum permissible number. The number is set in MD
28150 $MC_MM_NUM_VDIVAR_ELEMENTS.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program or machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14769
[Channel %1: ] Block %2 Spindle %3 Implicit auxiliary function %4 Buffer full
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number
%4 = Auxiliary function number
Definitions:
A maximum of 5 auxiliary functions of type "M" may be entered in an NC block. The upper limit is the total of pro-
grammed and implicitely generated M auxiliary functions. Implicit auxiliary functions M19 and M70 are generated, if in
MD35035 $MA_SPIND_FUNCTION_MASK, bit 19 has been set for M19 and/or bit 20 for M70. M19 is generated with
SPOS and SPOSA depending on the configuration. The same applies to M70 and transition into axis operation. The
address extension corresponds to the spindle number like it is output to the PLC.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Distribute the M auxiliary functions and spindle functions that implicitely generate M19 and M70 to several blocks.
- Deactivate any implicit auxiliary functions that are not required in MD35035 $MA_SPIND_FUNCTION_MASK, bit 19
and/or bit 20.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
196
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms