17600
[Channel %1: ] Block %2 preset on transformed axis %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The programmed PRESET axis is involved in the current transformation. This means that setting the actual value
memory (PRESET) is not possible for this axis.
Example:
Machine axis A should be set to the new actual value A 100 at the absolute position A 300.
:
N100 G90 G00 A=300
N101 PRESETON A=100
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Avoid preset actual value memory for axes which are participating in a transformation or deselect the transformation
with the keyword TRAFOOF.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17610
[Channel %1: ] Block %2 axis %3 involved in the transformation, action cannot be
carried out
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The axis is involved in the active transformation. It can therefore not execute the demanded action, traversing as posi-
tioning axis, enable for axis exchange.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Deselect the transformation with TRAFOOF ahead of time or remove the action from the part program block
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17620
[Channel %1: ] Block %2 approaching fixed point for transformed axis %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
In the displayed block, an axis is programmed for the fixed point approach (G75) that is involved in the active trans-
formation. Fixed point approach is not performed with this axis!
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Remove G75 instruction from the part program block or previously deselect transformation with TRAFOOF.
Program
Clear alarm with NC START or RESET key and continue the program.