Deactivate test run /PROGMODEDRYRUNOFF/ No. 64
Definitions:
Deactivate test run.
(VDI signal: rapid traverse override)
Not permitted if:
1. The nesting depth is too great
2. If there is a reorganize brake error
Possible actions:
1. Wait until previous ASUB has finished or cancel program
2. Cancel program
Delete all cancel alarms /CLEARCANCELALARM/ No. 49
Definitions:
Clears all alarms with the clear condition CANCELCLEAR (PI command, Cancel key)
Should not occur in any alarm
Delete distance to go / axis synchronization /DELDISTOGO_SYNC/ No. 15
Definitions:
Execute delete distance-to-go or axis synchronization.
(VDI signal: delete distance-to-go or follow-up mode)
Follow-up mode: e.g. on enabling axis control
Not permitted if:
1. The nesting depth is too great
2. If there is a reorganize brake error
Possible actions:
1. Cancel program
2. Cancel program
Delete marker /CLEARM/ No. 79
Definitions:
Delete marker (NC_block,CLEARM)
Should not occur in any alarm
Deselect overstore /OVERSTOEROFF/ No. 9
Definitions:
Deselect overstore (PI command)
Should not occur in any alarm
Digitizing active /DIGITIZEON/ No. 53
Definitions:
! Digitize function removed !
Activate digitization (PI command)
Should not occur in any alarm