NCK alarms
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10702
[Channel %1: ] NCK protection zone %2 violated during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Definitions:
The workpiece-related NCK protection zone has been violated. Note that another tool-related protection zone is still
active. The workpiece-related protected area can be traversed after a new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10703
[Channel %1: ] Channel-specific protection zone %2 violated during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
Definitions:
The workpiece-related channel-specific protection zone has been violated. Note that another tool-related protection
zone is still active. The workpiece-related protected area can be traversed after a new NC Start.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Protection zone can be traversed after a new NC Start.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10704
[Channel %1: ] Block %2 protection zone monitoring is not guaranteed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
New movements of a geometry axis which have been added could not be allowed for at the time of block preparation.
It is therefore not certain that the protection zones will not be violated. This is just a warning message without further
reactions.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Take other measures to ensure that the geomotry axes motion, including the additional motion, does not violate the
protection zones. (The warning comes nevertheless) or exclude additional motions.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
82
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms