Block %2 Compensation Block Not Possible; An Error Occurred While Handling The Function 'Syntax Check'; Block %2 Setint Instruction With Invalid Asup Input - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Program
Clear alarm with the RESET key. Restart part program
Continuation:
- Acknowledge the alarm by pressing the RESET key
- Repeat program selection
- Start the part program
14610
[Channel %1: ] Block %2 compensation block not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An alarm was output which could be eliminated basically via program correction. Since the error occurred in a program
which is processed from external, a compensation block/program correction is not possible.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Abort program with reset.
- Correct program on HMI or PC.
- Restart reloading (possibly with block search and interrupt location).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14615
[Channel %1: ] An error occurred while handling the function 'syntax check': identifier
%3
Parameters:
%1 = Channel number
%2 = Is not used
%3 = Error code
Definitions:
An error occurred while handling the function syntax check via the PI services _N_CHKSEL, _N_CHKRUN,
_N_CHKABO and _N_SEL_BL. Parameter %3 describes the error situation more closely:
Value
1: An invalid line number was transferred with the PI service _N_SEL_BL
2: An invalid line number for the range end was transferred with the PI service _N_CHKRUN
3: PI service _N_CHKSEL was activated although a block selection (PI service _N_SEL_BL) was active for the
selected program.
Reaction:
Alarm display.
Remedy:
Value
1: Supply PI service _N_SEL_BL with the correct line number
2: Supply PI service _N_CHKRUN with the correct line number for the range end
3: Ensure that the channel is in reset status before activating the PI service _N_CHKSEL.
Program
Clear alarm with the Delete key or NC START.
Continuation:
14650
[Channel %1: ] Block %2 SETINT instruction with invalid ASUP input
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Asynchronous subroutines (ASUBs) are subroutines that are executed following a hardware input (interrupt routine
started by a rapid NCK input).
The NCK input number must lie between 1 and 8. It is assigned a priority from 1 to 128 (1 is the highest priority) in the
SETINT instruction with the keyword PRIO = ... .
Example:
If NCK input 5 changes to "1 signal", the subroutine AB-HEB_ Z should be started with the highest priority.
N100 SETINT (5) PRIO = 1 ABHEB_Z
Restriction for SW PLC2xx: The number of the NCK input must be 1 or 2.