17833
[Channel %1: ] JOG a circle is active and JOG circles deactivated
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
A circular motion is active but 'JOG in circles' has been deactivated. The circular motion is canceled.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Reactivate 'JOG circles' and trigger JOG motion again.
Program
Clear alarm with the Delete key or NC START.
Continuation:
17900
[Channel %1: ] Block %2 axis %3 is no machine axis
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
At this point, the block context calls for a machine axis. This is the case with:
- G74 (reference point approach)
- G75 (fixed point approach)
If a geometry or additional axis identifier is used, then it must also be allowed as machine axis identifier (MD10000
$MN_AXCONF_MACHAX_NAME_TAB).
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use machine axis identifier when programming.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
18000
[Channel %1: ] Block %2 NCK-specific protection zone %3 wrong. Error code %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of NCK protection zone
%4 = Error specification
Definitions:
There is an error in the definition of the protection zone. The error number gives the specific reason for the alarm:
No.Meaning
1: Incomplete or conflicting contour definition.
2: Contour encompasses more than one surface area.
3: Tool-related protection zone is not convex.
4: If both boundaries are active in the 3rd dimension of the protection zone and both limits have the same value.
5: The number of the protection zone does not exist (negative number, zero or greater than the maximum number of
protection zones).
6: Protection zone definition consists of more than 10 contour elements.
7: Tool-related protection zone is defined as inside protection zone.
8: Incorrect parameter used.
9: Protection zone to be activated is not defined.
10: Incorrect modal G code used for protection zone definition.
11: Contour definition incorrect or frame activated.
12: Other, not further specified errors.