Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61803
[Channel %1: ] Block %2: Programmed axis not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed axis is not in the system.
Alarm triggered by following cycles: CYCLE83, CYCLE84, CYCLE840.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameter _AXN.
Check MD20050-20080.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61804
[Channel %1: ] Block %2: Progr. position exceeds reference point
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed intermediate position or actual position is behind the reference point.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61805
[Channel %1: ] Block %2: Value programmed absolute and incremental
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed intermediate position is both absolutely as well as incrementally programmed.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
475