Block %2 No Facing Axis For Diameter Programming Available; Block %2 Spindle %3 Gear Stage Change Not Possible; Block %2 Spindle %3 Gear Stage Change In %4 Not Possible - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Values for chamfers, roundings and modal roundings must be programmed with positive values only.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16510
[Channel %1: ] Block %2 no facing axis for diameter programming available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Diameter programming has been activated although no transverse axis with diameter programming has been applied.
Transverse axes can be applied with MD20100 $MC_DIAMETER_AX_DEF or MD30460
$MA_BASE_FUNCTION_MASK bit2 for diameter programming.
Diameter programming can be applied through:
- basic position DIAMON or DIAM90 of the G 29 group during booting
- programming of DIAMON or DIAM90
- programming of DIAMONA[AX], DIAM90A[AX] or DAC, DIC, RAC, RIC
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
When programming DIAMON/DIAM90, a traverse axis must be configured via MD20100 $MC_DIAMETER_AX_DEF.
When programming DIAMONA[AX], DIAM90A[AX] or DAC, DIC, RAC, RIC, the AX axis must be a transverse axis for
diameter programming configured via MD30460 $MA_BASE_FUNCTION_MASK bit2.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16600
[Channel %1: ] Block %2 spindle %3 gear stage change not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number
Definitions:
The programmed speed is outside the speed range of the set gear stage. In order to execute the programmed speed,
the gear stage must be changed. In order to be able to execute the automatic gear stage change (M40 is active), the
spindle must be in speed control operation.
The alarm will no longer be output after having set bit 30 (0x40000000) in MD11410
$MN_SUPPRESS_ALARM_MASK. However, the function will not be affected by this.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
The changeover to speed control operation is performed by programming M3, M4 or M5. The M functions can be writ-
ten together with the S word in the same block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16605
[Channel %1: ] Block %2 Spindle %3 Gear stage change in %4 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number
%4 = Gear stage
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
227

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents