[Channel %1:] Block %2: Check Probe / Machining Plane; [Channel %1:] Block %2: Adapt Array Size %4; Block %2: Probe Will Collide With The Carrier Of The Reference Groove; Block %2: Protocol File Too Small, Check Md11420 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
61415
[Channel %1: ] Block %2: Check probe / machining plane
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE971
Remedy:
Enter permissible probe for machining plane:
- For 840D: Check the variables _TP[x,8] and _TPW[x,8] in GUD6
- For 840D sl: Check the setting data 54633 $SNS_MEA_TP_TYPE and 54648 $SNS_MEA_TPW_TYPE
or change the machining plane.
61416
[Channel %1: ] Block %2: adapt array size %4!
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
For 840D:
Match _CVAL entry to the number of existing probe and calibration block data fields, that means:
- Adapt _TP[ ]/_CVAL[0] field size, or
- Adapt _WP[ ]/_CVAL[1] field size, or
- Adapt _KP[ ]/_CVAL[2] field size, or
- Adapt _TWP[ ]/_CVAL[3].
For 840D sl:
Check machine data for the number of probe and calibration block data fields, that means:
- Workpiece probe
- Calibration block
- Workpiece probe in MCS 51602$MNS_MEA_CAL_TP_NUM or
- Workpiece probe in WCS 51603$MNS_MEA_CAL_TPW_NUM
61417
[Channel %1: ] Block %2: Probe will collide with the carrier of the reference groove.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE973
Remedy:
Take up collision-free initial position of the axes involved in the measuring process.
61418
[Channel %1: ] Block %2: Protocol file too small, check MD11420:
LEN_PROTOCOL_FILE.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm can be triggered by following measuring cycle: CYCLE106
Remedy:
Check MD11420: LEN_PROTOCOL_FILE.
61419
[Channel %1: ] Block %2: Check probe calibration with reference to center of ball/
circumference of ball.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977, CYCLE978,
CYCLE979, CYCLE997, CYCLE998
Remedy:
The workpiece probe must be calibrated according to its use in the measuring cycles.
448
51600$MNS_MEA_CAL_WP_NUM or
51601$MNS_MEA_CAL_EDGE_NUM or
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0