NCK alarms
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Use only the feed type G94 or G95 in the thread cutting functions.
After G33 and before G63, deselect the thread cutting function with G01.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16715
[Channel %1: ] Block %2 axis %3 spindle not in standstill
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number
Definitions:
In the applied function (G74, reference point approach), the spindle must be stationary.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program M5 or SPOS/SPOSA in front of the defective block in the part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16720
[Channel %1: ] Block %2 axis %3 thread pitch is zero
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
No pitch was programmed in a thread block with G33 (thread with constant pitch) or G331 (rigid tapping).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
The thread pitch must be programmed for the specified geometry axis under the associated interpolation parameters.
X -> I
Y -> J
Z -> K
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16730
[Channel %1: ] Block %2 axis %3 wrong parameter
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
In G33 (tapping with constant pitch) the pitch parameter was not assigned to the axis that determines the velocity.
For longitudinal and face threads, the thread pitch for the specified geometry axis must be programmed under the
associated interpolation parameter.
X -> I
Y -> J
Z -> K
For taper threads, the address I, J, K depends on the axis with the longer path (thread length). A 2nd lead for the other
axis is, however, not specified.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Assign lead parameters to the axis that determines the velocity.
236