16957
[Channel %1: ] Stop-Delay area is suppressed
Parameters:
%1 = Channel ID
Definitions:
The program area (Stop-Delay area), which is bracketed by DELAYFSTON and DELAYFSTOF, could not be acti-
vated. Every stop therefore becomes effective immediately and is not delayed!
This occurs every time, when braking into a stop Stop-Delay area, i.e. a braking process starts before the Stop-Delay
area and ends not earlier than in the Stop-Delay area.
If the Stop-Delay area is entered with override 0, the Stop-Delay area can also not be activated
Example: a G4 before the Stop-Delay area allows the user to reduce the override to 0. The next block in the Stop-
Delay area then starts with override 0 and the alarm situation described occurs.
MD11411 $MN_ENABLE_ALARM_MASK, bit 7 switches on this alarm.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
MD11550 $MN_STOP_MODE_MASK and language command DELAYFSTON DELAYFSTOF
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
16959
[Channel %1: ] Action %2<ALNX> prohibited during simulation block search.
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
The function (2nd parameter) must not be activated during simulation search.
Reaction:
Alarm display.
Remedy:
Wait for search end.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16960
[Channel %1: ] Action %2<ALNX> prohibited during EXECUTE PROGRAM AREA.
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
The function (2nd parameter) must not be activated during EXECUTE PROGRAM AREA.
Reaction:
Alarm display.
Remedy:
Wait for end of program area EXECUTE.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16961
[Channel %1: ] Action %2<ALNX> prohibited during syntax check.
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
The function (2nd parameter) must not be activated during the syntax check.
Comment: The syntax check is served by the following PI services:
_N_CHKSEL _N_CHKRUN _N_CHKABO
Reaction:
Alarm display.
Remedy:
Wait for the end of the syntax check, or
Cancel the syntax check with reset, or
Cancel the syntax check with PI _N_CHKABO.
Program
Clear alarm with the Delete key or NC START.