NCK alarms
10882
[Channel %1: ] Block %2 activation of chamfers or radii (non-modal) without traversing
movement in the block
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No chamfer or radius has been inserted between 2 linear or circle contours (edge breaking) because:
There is no straight line or circle contour in the plane
There is a movement outside the plane
A plane change has taken place
The permissible number of empty blocks without traversing information (dummy blocks) has been exceeded.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Correct the part program according to the above error
description or change the number of dummy blocks in the channel-specific MD20200
$MC_CHFRND_MAXNUM_DUMMY_BLOCKS to comply with the maximum number allowed for in the program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10883
[Channel %1: ] Block %2 chamfer or fillet has to be reduced
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
This alarm is output, if at least one of the relevant blocks when inserting chamfers or radii is so short, that the contour
element to be inserted must be reduced against its originally programmed value. The alarm occurs only if bit 4 is set
in the MD11411 $MN_ENABLE_ALARM_MASK. Otherwise, the chamfer or radius is adapted without an alarm being
output.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify NC program of continue program without modifications after CANCEL and Start or with Start alone.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10890
[Channel %1: ] Block %2 overflow of local block buffer when calculating splines
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The maximum permissible number of empty blocks is limited by a machine data.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
- Modify part program
- Modify machine data
- Check whether SBL2 is activated. With SBL2, a block is generated from each part program line which can lead to
exceeding the maximum permissible number of empty blocks between two traversing blocks.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
98
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0