22038
[Channel %1: ] Block %2 Axis/Spindle %3 'Delete synchronism override' is being
ignored
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis/spindle number
Definitions:
VDI interface signal DB31..,DBX31.7 'Correct synchronism' is being ignored, because VDI interface signal
DB31..,DBX31.6 'Delete synchronism override' has been set.
Reaction:
Alarm display.
Remedy:
Reset the two VDI interface signals DB31..,DBX31.6 'Correct synchronism' and DB31..,DBX31.7 'Delete synchronism
override', before the latter signal can be set again.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22040
[Channel %1: ] Block %3 spindle %2 is not referenced with zero marker
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
Definitions:
The current position is not referenced with the measuring system position although reference is made to it.
Reaction:
Alarm display.
Remedy:
Correct NC part program. Create the zero mark synchronization by positioning, by rotation (at least 1 revolution) in
speed control mode or G74 before switching the alarm generating function on.
If this has been intentionally programmed, the alarm can be suppressed in the cyclic check with position control
already enabled by means of MD11410 $MN_SUPPRESS_ALARM_MASK Bit21 = 1.
Program
Clear alarm with the Delete key or NC START.
Continuation:
22050
[Channel %1: ] Block %3 spindle %2 no transition from speed control mode to position
control mode
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
Definitions:
- An oriented spindle stop (SPOS/SPOSA) has been programmed or the position control of the spindle was switched
on with SPCON but no spindle encoder has been defined.
- When switching on the position control, the spindle speed is greater than the limiting speed of the measuring system.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Spindle without attached encoder: Any NC language elements requiring the encoder signals must not be used.
Spindle with attached encoder: Enter the number of spindle encoders used in the MD30200 $MA_NUM_ENCS.
Program
Clear alarm with the RESET key. Restart part program
Continuation: