[Channel %1:] Illegal Auxiliary Function Configured %2 %3 %4; [Channel %1:] Geometry Axis %2 Must Not Be Declared A Rotary Axis; [Channel %1:] Spindle %2 Declaration As Rotary Axis Missing - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
4185
[Channel %1: ] Illegal auxiliary function configured %2 %3 %4
Parameters:
%1 = Channel number
%2 = Type of auxiliary function
%3 = Extension
%4 = Auxiliary function value
Definitions:
An auxiliary function has been illegally configured.
Predefined auxiliary functions cannot be reconfigured by user-defined auxiliary functions.
See:
MD22010 $MC_AUXFU_ASSIGN_TYPE[n]
MD22020 $MC_AUXFU_ASSIGN_EXTENSION[n]
MD22030 $MC_AUXFU_ASSIGN_VALUE[n]
MD22035 $MC_AUXFU_ASSIGN_SPEC[n]
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Reconfigure the auxiliary function.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4200
[Channel %1: ] Geometry axis %2 must not be declared a rotary axis
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
The geometry axes represent a Cartesian coordinate system and therefore the declaration of a geometry axis as rotary
axis leads to a definition conflict.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Remove rotary axis declaration for this machine axis.
For this purpose, the geometry axis index for the displayed geometry axis must be determined by means of MD20060
$MC_AXCONF_GEOAX_NAME_TAB. The channel axis number is stored with the same index in MD20050
$MC_AXCONF_GEOAX_ASSIGN_TAB. The channel axis number minus 1 provides the channel axis index under
which the machine axis number is found in MD20070 $MC_AXCONF_MACHAX_USED.
Program
Switch control OFF - ON.
Continuation:
4210
[Channel %1: ] Spindle %2 declaration as rotary axis missing
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
If a machine axis is to be operated as a spindle, this machine axis must be declared as a rotary axis.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
34
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents