Block %2 Transformation Not Available; Block %2 Spline Active At Transformation Change - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

7: The DRF movement for this axis cannot be executed as a velocity override of the path with
the handwheel is active and the axis belongs to the path
8: The DRF movement for this axis cannot be executed as the contour handwheel is active with
this handwheel and the axis belongs to the path
9: The DRF movement for this axis cannot be executed as the axis is a PLC axis with handwheel
override that is active with this handwheel
10: The DRF movement for this axis cannot be executed as the axis is active as reciprocating axis
with handwheel override with this handwheel
Reaction:
Alarm display.
Remedy:
Use the handwheel for one purpose at a time only.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
14401
[Channel %1: ] Block %2 transformation not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The required transformation is not available.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
Modify part program; program defined transformations only.
Check MD 24... $MC_TRAFO_TYPE_... (assigns the transformation to part program instruction).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14402
[Channel %1: ] Block %2 spline active at transformation change
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A change of transformation is not allowed in a spline curve section. A series of spline blocks must be concluded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14403
[Channel %1: ] Block %2 preprocessing and main run might not be synchronized
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Positioning axis runs cannot be accurately calculated beforehand. Consequently, the position in the MCS is not known
exactly. It might therefore be possible that a change in the multiple significance of the transformation has been per-
formed in the main run although no provision was made for this in the preprocessing run.
Reaction:
Alarm display.
Remedy:
Modify part program. Synchronize preprocessing run and main run.
Program
Clear alarm with the Delete key or NC START.
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
179

Hide quick links:

Advertisement

Table of Contents
loading