NCK alarms
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Add the correct identifier.
Program
Switch control OFF - ON.
Continuation:
4040

[Channel %1: ] Axis identifier %2 not consistent with machine data %3

Parameters:
%1 = Channel number
%2 = String: Axis identifier
%3 = String: MD identifier
%4 = There are not enough channel axes entered in the MD displayed.
Definitions:
The use of the specified axis identifier in the displayed MD is not consistent the channel's axis configuration stated in
the MD20070 $MC_AXCONF_MACHAX_USED and MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
Check and correct the identifier used in the MD10000 $MN_AXCONF_MACHAX_NAME_TAB, MD20080
$MC_AXCONF_CHANAX_NAME_TAB and/or MD20060 $MC_AXCONF_GEOAX_NAME_TAB.
Program
Switch control OFF - ON.
Continuation:
4045

[Channel %1: ] Conflict between machine data %2 and machine data %3

Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = String: MD identifier
Definitions:
Using the specified machine data %1 leads to a conflict with machine data %2.
Reaction:
NC not ready.
Mode group not ready, also effective for single axes.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Correct the specified machine data.
Program
Switch control OFF - ON.
Continuation:
24
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0