Block %2 Frame: Illegal Switchover Of Geometry Axes; Block %2 Frame: Type Conflict; Block %2 Language Change Not Possible:%3 - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify machine data.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
18313
[Channel %1: ] Block %2 frame: illegal switchover of geometry axes
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
It is not allowed to change the geometry axis assignment because the current frame contains rotations.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Change NC program or set other mode with MD10602 $MN_FRAME_GEOAX_CHANGE_MODE.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
18314
[Channel %1: ] Block %2 frame: type conflict
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
It is not possible to chain global frames and channel-specific frames. The alarm occurs if a global frame is programmed
with a channel axis name and no machine axis on this NCU is assigned to the channel axis. Channel-specific frames
cannot be programmed with machine axis names if there is no corresponding channel axis on this NCU.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
18400
[Channel %1: ] Block %2 language change not possible:%3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Cause
Definitions:
The selection of an external NC language is not possible due to the reason specified. The following reasons are pos-
sible (see parameter 3):
1. Invalid machine data settings
2. Active transformation
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remedy the specified cause of the error before selecting the language.
296
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents