Block %2: Tool Carrier Not Parallel To The Geometry Axes; Current Measuring Speed Is Not Identical To The Calibration Speed; Block %2: Check Holder Angle; Block %2: Check Insert Angle And Clearance Angle - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
61442
[Channel %1: ] Block %2: Tool carrier not parallel to the geometry axes
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycle: CYCLE982
Remedy:
As a result of incorrect positioning of the orientable tool carrier, tool lengths L1,2,3 are not parallel to the geometry
axes.
Optimize the axes of the tool carrier.
61443
[Channel %1: ] Block %2: Advance angle _INCA=0 or greater/less than +/-90° or +/-120°
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycle: CYCLE979
Remedy:
Check the value in the parameter advance angle _INCA.
If 3-point measurement is selected, _INCA must not be greater/less than +/-120°, and with 4-point measurement
_INCA must not be greater/less than +/-90°.
The advance angle _INCA must always be parameterized unequal to "zero".
61444
[Channel %1: ] Block %2: Current measuring speed is not identical to the calibration
speed
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE974, CYCLE994, CYCLE977, CYCLE978,
CYCLE979, CYCLE997, CYCLE998
E_MS_CAN, E_MS_HOL, E_MS_POC, E_MS_PIN, E_MS_SPI
Remedy:
1. Repeat the calibration on the basis of the desired measuring speed.
2. Match the current measuring speed to the calibration speed.
Note: In each case, the relevant calibration speed is stored in each calibration data record.
61445
[Channel %1: ] Block %2: Check holder angle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE982
Remedy:
Check the entry for the holder angle in the tool offset.
For cutting edge positions 1-4, the holder angle must be greater than or equal to 90° and less than 180°,
for cutting edge positions 5-8, it must be greater than 0° and less than 90°.
61446
[Channel %1: ] Block %2: Check insert angle and clearance angle
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE982
Remedy:
Check the entry for the insert angle / clearance angle in the tool offset