NCK alarms
61025
[Channel %1: ] Block %2: Check tool carrier position
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61026
[Channel %1: ] Block %2: Cycle cannot be executed with NC function %4.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61027
%[[Channel %1: ] Block %2: %]Subroutine %4 does not exist
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE62
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check CYCLE62 call
- Check whether the subroutines specified on CYCLE62 call exist in the program storage
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61028
[Channel %1: ] Block %2: Contour name %4 too long
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE62
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- use shorter contour name
Program
Clear alarm with the RESET key. Restart part program
Continuation:
376
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms