Drive Encoder: Sensor Module Configuration Not Supported; Drive Encoder: Configuration Position Tracking - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

SINAMICS alarms
207553
<location>Drive encoder: Sensor Module configuration not supported
Message value:
Encoder data set: %1, first incorrect bit: %2, incorrect parameter: %3
Drive object:
SERVO_COMBI, SERVO_SINUMERIK828
Reaction:
OFF2 (IASC/DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The Sensor Module does not support the requested configuration.
For incorrect p0430 (cc = 0), the following applies:
- In p0430 (requested functions), at least 1 bit was set that is not set in r0458 (supported functions) (exception: Bit 19,
28, 29, 30, 31).
- p1982 > 0 (pole position identification requested), but r0458.16 = 0 (pole position identification not supported).
For incorrect p0437 (cc = 1), the following applies:
- In p0437 (requested functions), at least 1 bit was set that is not set in r0459 (supported functions).
Fault value (r0949, interpret hexadecimal):
ddccbbaa hex
aa: encoder data set number
bb: first incorrect bit
cc: incorrect parameter
cc = 0: incorrect parameter is p0430
cc = 1: incorrect parameter is p0437
cc = 2: incorrect parameter is r0459
dd: reserved (always 0)
Remedy:
- check the encoder parameterization (p0430, p0437).
- check the pole position identification routine (p1982).
- use the matching encoder evaluation (r0458, r0459).
See also: p0430 (Sensor Module configuration), p0437 (Sensor Module configuration extended), r0458 (Sensor Mod-
ule properties), r0459 (Sensor Module properties extended), p1982 (Pole position identification selection)
207555
<location>Drive encoder: Configuration position tracking
Message value:
Component number: %1, encoder data set: %2, drive data set: %3, fault cause: %4
Drive object:
SERVO_COMBI, SERVO_SINUMERIK828
Reaction:
OFF2 (IASC/DCBRAKE, NONE, OFF1, OFF3, STOP1, STOP2)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
The configuration of the position tracking is not supported.
Position tracking can only be activated for absolute encoders.
For linear axes, it is not possible to simultaneously activate the position tracking for load and measuring gears.
Fault value (r0949, interpret hexadecimal):
ddccbbaa hex
aa = encoder data set
bb = component number
cc = drive data set
dd = fault cause
dd = 00 hex = 0 dez
An absolute encoder is not being used.
dd = 01 hex = 1 dez
Position tracking cannot be activated because the memory of the internal NVRAM is not sufficient or a Control Unit
does not have an NVRAM.
dd = 02 hex = 2 dez
For a linear axis, the position tracking was activated for the load and measuring gear.
dd = 03 hex = 3 dez
Position tracking cannot be activated because position tracking with another gear ratio, axis type or tolerance window
has already been detected for this encoder data set.
dd = 04 hex = 4 dez
A linear encoder is being used.
See also: p0404 (Encoder configuration effective), p0411 (Measuring gear, configuration)