Blank Must Be Closed Contour; Collision Through Approach; Axis In Negative Range - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Remedy:
- Check cutting edge position in tool management
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61739
%[[Channel %1: ] Block %2: %]Blank must be closed contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE952
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check whether the blank contour is closed
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61740
%[[Channel %1: ] Block %2: %]Collision through approach
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE952
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Select the starting position to enable collision-free approach of the contour
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61741
%[[Channel %1: ] Block %2: %]Axis in negative range
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE952
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Check the position of the axis in the ordinate
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
473