6581

NC user memory full

Definitions:
The DRAM file system of the user area is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program
Clear alarm with the Delete key or NC START.
Continuation:
6582

NC machine OEM memory full

Definitions:
The DRAM file system of the machine OEM area is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program
Clear alarm with the Delete key or NC START.
Continuation:
6583

NC system memory full

Definitions:
The DRAM file system of the system area (Siemens) is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program
Clear alarm with the Delete key or NC START.
Continuation:
6584
NC memory limit TMP reached
Definitions:
The DRAM file system of the TMP (temporary) area is full. The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Increase MD18351 $MN_MM_DRAM_FILE_MEM_SIZE bzw. MD18355 $MN_MM_T_FILE_MEM_SIZE or switch off
the precompilation of individual or all cycles
Program
Clear alarm with the Delete key or NC START.
Continuation:
6585
NC external memory limit reached
Definitions:
The DRAM file system of the external area (execution of the external drive) is full.
The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Load the files to be executed explicitly into the NCK.
Program
Clear alarm with the Delete key or NC START.