Declaration In Md %1 Is Not Allowed For Axis %2; Declaration In Md %1 Index %2 Is Not Allowed; Axis %1 Function %2 %3 And %4 Not Allowed - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Alter MD10368 $MN_HW_ASSIGN_DIG_FASTOUT or
MD10364 $MN_HW_ASSIGN_ANA_FASTOUT.
Program
Switch control OFF - ON.
Continuation:
4300

Declaration in MD %1 is not allowed for axis %2.

Parameters:
%1 = String: MD identifier
%2 = Axis name, spindle number
Definitions:
The axis cannot be operated as competing positioning axes,
for example because the axis is the slave axis within a closed gantry group or a gantry group to be closed.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Reset MD30450 $MA_IS_CONCURRENT_POS_AX for
the axis concerned.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4310

Declaration in MD %1 index %2 is not allowed.

Parameters:
%1 = String: MD identifier
%2 = Index: MD array index
Definitions:
The machine data values must be written in the array in ascending order.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Correct the MD.
Program
Teileprogramm neu starten.Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Continuation:
4320

Axis %1 function %2 %3 and %4 not allowed

Parameters:
%1 = String: Axis identifier
%2 = String: MD identifier
%3 = String: Bit
%4 = String: MD identifier
Definitions:
The functions declared by the specified machine data cannot simultaneously be active for one axis.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Deactivate one of the functions.
38
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents