10706
[Channel %1: ] NCK protection zone %2 reached with axis %3 during manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
Definitions:
The workpiece-related NCK protection zone has been reached with the specified axis. Note that another tool-related
protection zone is still active. The workpiece-related protection zone can be traversed when the PLC has issued an
enable signal.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Protection zone can be traversed after enable signal from
PLC.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10707
[Channel %1: ] Channel-specific protection zone %2 reached with axis %3 during
manual mode
Parameters:
%1 = Channel number
%2 = Protection zone number
%3 = Axis name
Definitions:
The workpiece-related channel-specific protection zone has been reached with the specified axis. Note that another
tool-related protection zone is still active. The workpiece-related protection zone can be traversed when the PLC has
issued an enable signal.
Reaction:
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Protection zone can be traversed after enable signal from
PLC.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
10720
[Channel %1: ] Block %3 axis %2 software limit switch %4
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Block number, label
%4 = String (+ or -)
Definitions:
The path programmed for the axis violates the currently valid software limit switch. The alarm is activated when pre-
paring the part program block.
If bit 11=0 in the machine data MD11411 $MN_ENABLE_ALARM_MASK, this alarm is issued instead of alarm 10722.
If bit 11 is set in the machine data MD11411 $MN_ENABLE_ALARM_MASK, an expanded diagnostics option is
offered for the software limit switch violation. The condition for activation is the presence of the ALUN* alarm file in the
HMI.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.