Block %2: Thread Pitch Incorrectly Defined; Block %2: %]Type Of Machining Incorrectly Defined; Block %2: %]No Feed Programmed In Cycle; Block %2: Incorrect Configuration Of Geometry Axes - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
61001
[Channel %1: ] Block %2: Thread pitch incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE84, CYCLE840, CYCLE96, CYCLE97.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameter for the thread size or setting for the pitch (contradict each other).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61002
%[[Channel %1: ] Block %2: %]Type of machining incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The value of the VARI parameter for the machining has been incorrectly specified. Alarm triggered by following cycles:
SLOT1, SLOT2, POCKET1 to POCKET4, CYCLE63, CYCLE64, CYCLE71, CYCLE72, CYCLE76, CYCLE77,
CYCLE93, CYCLE95, CYCLE97, CYCLE98.
Remedy:
Modify VARI parameter.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61003
%[[Channel %1: ] Block %2: %]No feed programmed in cycle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The parameter for the feed has been incorrectly specified. Alarm triggered by following cycles: CYCLE71, CYCLE72.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify feed parameter.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61004
[Channel %1: ] Block %2: Incorrect configuration of geometry axes
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The geometry-axes sequence is wrong. CYCLE328
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
--
Program
Clear alarm with the RESET key. Restart part program
Continuation:
370
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
Alarms

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 828d

Table of Contents