Block %2: Too Many Restrictions, Use Rectangular Pocket; Block %2: Illegal Machining Direction; Block %2: Plane Infeed Too Large, Residual Corners Remain; Block %2: Illegal Machining Direction, Residual Corners Are Left Over - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

61265
[Channel %1: ] Block %2: Too many restrictions, use rectangular pocket
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In face milling a maximum of only 3 sides can be delimited.
Alarm triggered by following cycle: CYCLE61
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Use pocket cycle.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61266
[Channel %1: ] Block %2: Illegal machining direction
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In face milling, the delimitations and the direction of machining do not match.
Alarm triggered by following cycle: CYCLE61
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select another direction of machining.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61267
[Channel %1: ] Block %2: Plane infeed too large, residual corners remain
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In face milling, the plane infeed must not exceed 85%.
Alarm triggered by following cycle: CYCLE61
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Select a smaller plane infeed, as otherwise residual corners will be left over.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61268
[Channel %1: ] Block %2: Illegal machining direction, residual corners are left over.
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In face milling, the machining direction does not match the selected delimitations.
Alarm triggered by following cycle: CYCLE61.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms