Block %2 Absolute Programming Of The Orienting Rotation; Block %2 Orientation Angles/Orientation Vector Components Programmed; Block %2 Too Many Initialization Values Given - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14128
[Channel %1: ] Block %2 absolute programming of the orienting rotation with active
ORIROTC.
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The rotation of orientation (3rd degree of freedom of orientation for 6-axis transformations) has been programmed with
G code ORIROTC active. This is not possible, as the rotation of orientation is oriented relatively to the path tangent
when ORIROTC is active.
With ORIROTC, it is only possible to program the angle of rotation THETA that indicates the angle
of the rotation vector to the path tangent.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14129
[Channel %1: ] Block %2 orientation angles and orientation vector components
programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An orientation angle and components of an orientation vector were programmed at the same time.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14130
[Channel %1: ] Block %2 too many initialization values given
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
On assigning an array by means of SET, more initialization values than existing array elements have been specified
in the program run.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of initialization values.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0