Block %2 Fz Active, But No Tool Offset, Tool %3; Number Of Teeth Of The Active D Number %4 Of Tool %3 Is Zero - Siemens Sinamics S120 Diagnostic Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

NCK alarms
Remedy:
Modify the program so that no reference is possible to the program itself.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10865
[Channel %1: ] Block %2 FZ active, but no tool offset, tool %3
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
%3 = Tool
Definitions:
For the displayed traversing block a tooth feedrate is active, but no tool offset.
Traversing can be performed after the error has been acknowledged. For calculation of the effective feedrate one tooth
per revolution will be assumed.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Check the NC program for correct tool selection and correct it, if required; then continue the program with NC start.
Or:
Continue the NC program with NC start. For calculation of the effective feedrate one tooth per revolution is assumed.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10866
[Channel %1: ] Block %2 FZ is active, but the number of teeth of the active D number
%4 of tool %3 is zero.
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Identifier
%4 = D number
Definitions:
Tooth feedrate is active for the displayed traversing block, but a D number of 0 is selected with $TC_DPNT (number
of teeth).
Traversing can be performed after acknowledgement of the error. For calculation of the effective feedrate one tooth
per revolution is assumed.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Check the NC program for correct tool selection and correct it, if required;
then continue the NC program with NC start.
Or:
Continue the NC program with NC start. The feedrate will be calculated assuming
1 tooth.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: