NCK alarms
6411

[Channel %1: ] Tool %2 has reached its prewarning limit with D = %4

Parameters:
%1 = Channel number
%2 = Tool identifier (name)
%3 = -Not used-
%4 = D number
Definitions:
Tool monitoring: This message informs that the specified D offset has reached its prewarning limit for a time-, quantity-
or wear-monitored tool. If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
If the function additive offset is being used, additive offset monitoring may be active instead of tool wear monitoring.
The actual type of tool monitoring is a tool property (see $TC_TP9).
If replacement tools are not being used, the duplo number specified has no meaning.
The alarm originates during NC program execution.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
For information only. The user must decide what to do.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6412

[TO unit %1: ] Tool %2 has reached its monitoring limit with D = %4

Parameters:
%1 = TO unit
%2 = Tool identifier (name)
%3 = -Not used-
%4 = D number
Definitions:
Tool monitoring: This message informs that the specified D offset has reached its prewarning limit for a time-, quantity-
or wear-monitored tool. If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
If the function additive offset is being used, additive offset monitoring may be active instead of tool wear monitoring.
The actual type of tool monitoring is a tool property (see $TC_TP9).
If replacement tools are not being used, the duplo number specified has no meaning.
The alarm is triggered through the HMI or PLC (=OPI interface). The channel context is not defined. The TO unit was
specified for this reason (see MD28085 $MC_MM_LINK_TOA_UNIT).
Reaction:
Interface signals are set.
Alarm display.
Remedy:
For information only. The user must decide what to do.
Program
Clear alarm with the Delete key or NC START.
Continuation:
6413

[Channel %1: ] Tool %2 has reached its monitoring limit with D = %4

Parameters:
%1 = TO unit
%2 = Tool identifier (name)
%3 = -Not used-
%4 = D number
Definitions:
Tool monitoring: This message informs that the specified D offset has reached its prewarning limit for a time-, quantity-
or wear-monitored tool. If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
If the function additive offset is being used, additive offset monitoring may be active instead of tool wear monitoring.
The actual type of tool monitoring is a tool property (see $TC_TP9).
If replacement tools are not being used, the duplo number specified has no meaning.
The alarm originates during NC program execution.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
For information only. The user must decide what to do.
Program
Clear alarm with the Delete key or NC START.
Continuation: