Siemens Sinamics S120 Diagnostic Manual page 928

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

List of actions
Stop processing at block limit (program) /PROG_STOP/ No. 41
Definitions:
Stop the processing at the block boundary. (NC block, M00/M01)
Should not occur in any alarm
Stop processing at block limit (VDI) /STOPPROGATBLOCKEND/ No. 42
Definitions:
Stop the processing at the block boundary.
(Alarm, VDI signal: NC stop at the block boundary)
Should not occur in any alarm
Stop single block because of mode group (type A) /BAGSTOP_SLBTYPA/ No. 37
Definitions:
Stop on account of mode group single block.
(VDI signal: single type A, after stop in another channel of this mode group)
Should not occur in any alarm
Stop single block because of mode group (type B) /BAGSTOPATEND_SLBTYPB/ No. 38
Definitions:
Stop on account of mode group single block.
(VDI signal: single type B, after stop at the block boundary in the other channel of this mode group)
Should not occur in any alarm
User interrupt /INTERRUPT_SIGNAL/ No. 87
Definitions:
Execute an "ASUB" user interrupt.
(VDI signal, ASUB interface, digital-analog interface)
Collective event for all interrupt signals.
This event decides which actual
interrupt one would like to trigger.
Possible candidates are:
INTERRUPT
INTERRUPTFASTLIFTOFF
INTERRUPTBLSYNC
INTERRUPT_TOPROG_NOEPOS
INTERRUPT_START
See INTERRUPT
User interrupt (initial setting) /INTERRUPT_START/ No. 86
Definitions:
Activate a user interrupt "ASUB".
Is only executed in channel status READY.
(VDI signal, ASUB interface, digital-analog interface)
See INTERRUPT
928
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0