17630
[Channel %1: ] Block %2 referencing for transformed axis %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
In the displayed block, an axis is programmed for reference point approach (G74) that is involved in the active trans-
formation. Reference point approach is not performed with this axis!
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Remove G74 instruction, or the machine axes involved in transformation, from the part program block or previously
deselect the transformation with TRAFOOF.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17640
[Channel %1: ] Block %2 spindle operation for transformed axis %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The axis programmed for the spindle operation is involved in the current transformation as geometry axis. This is not
allowed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
First switch off the transformation function.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17650
[Channel %1: ] Block %2 machine axis %3 not programmable
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The machine axis cannot be used in an active transformation. You may be able to program the function in a different
coordinate system. For example, it may be possible to specify the retraction position in the basic coordinate system
or the workpiece coordinate system. The axis identifier is used to select the coordinate system.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Deactivate the transformation or use another coordinate system.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
17800
[Channel %1: ] Block %2 illegally coded position programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The position number n specified with the keyword FP=n is not permissible. Two (2) absolute axis positions can be
directly defined as fixed points by the axis-specific machine data MD30600 $MA_FIX_POINT_POS[n].
Or, if position numbers 3 and/or 4 are to be used, then machine data MD30610 $MA_NUM_FIX_POINT_POS must
be set accordingly.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
285