61044
%[[Channel %1: ] Block %2: %]Illegal character(s) in file name: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE952, CYCLE63, CYCLE64
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Remove illegal character from file name
Permitted characters are: letters, figures, underscore, slash with path name
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61045
[Channel %1: ] Block %2: Job list not found: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE208
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The specified job list could not be found.
Check name and contents of job list.
The job list must be in the same workpiece as the part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61046
[Channel %1: ] Block %2: Part program not found in job list: %4
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE208
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Part program (main program) not found in specified job list in respective channel.
Check name and contents of job list.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61047
[Channel %1: ] Block %2: Label name %4 too long
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE62
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Alarms
Diagnostics Manual, 07/2010, 6FC5398-8BP40-0BA0
NCK alarms
381