CHAPTER 8
This chapter describes the programming of the CC-Link IE Controller Network module.
8.1

Program Example of a Single Network System

The programming procedure of when communications are performed in a single network system is described in Page
267, Section 8.1.1 to Page 285, Section 8.1.6.
8.1.1

System configuration

Configure the system using the procedures described in this section.
(1) System configuration example
Configure the system shown below.
The following is a single network system where a CC-Link IE Controller Network module is mounted on the slot 0
of the base unit.
Control station
No.1
Normal station
No.4
(2) Wiring example
Connect optical fiber cable from the OUT connector to the IN connector.
The optical fiber cable is not required to be connected in the station No. sequence. (
CC-Link IE Controller Network module
Control station
Station No.1
IN
OUT
PROGRAMMING
Network No.1
Normal station
Normal station
Station No.2
Station No.3
IN
OUT

CHAPTER 8 PROGRAMMING

Normal station
No.2
Normal station
No.3
Page 162, Section 5.5)
Normal station
Station No.4
IN
OUT
IN
8