(3) Function
(a) RTMWR instruction overview
This instruction is used to write clock data to a programmable controller on another station.
The target station is specified in Target station network No. (Jn) and Target station No. (n2).
Upon completion of the request to the target station, the completion device (D2) turns ON.
[Own station]
CPU module
(D1)
(b) Target stations available for specification
• Target network
In addition to CC-Link IE Controller Network, stations in the following networks can be also specified.
• CC-Link IE Field Network
• MELSECNET/H
• MELSECNET/10
• Ethernet
• Target station's CPU type
The RTMWR instruction is executable only when the target station is QCPU, RCPU, or LCPU.
470
CC-Link IE Controller
Network module
Channel 1
RTMWR
Channel n
Channel 8
[Target station]
CPU module
Clock data
Network module